Manufacturers > Eclipse > Shutoff and Control Valves
Click on an item for information

Industrial Shutoff and Control Valves

All Eclipse Shutoff and Control Valves

Eclipse
   
Click logo for manufacture site
Butterfly Valves
Eclipse Butterfly Valves
 

Eclipse Butterfly Valves are designed to control air and gas flow to all types of combustion systems. They should not be used as tight shut-off valves.

Links:

Industrial Furnace Gas Burners

Adjustable Limited Orfices
Eclipse Adjustable Limited Orfices
 

Eclipse ALO-R Valves are needle and seat type valves designed to provide accurate gas flow adjustment when installed in gas lines feeding nozzle mix burners. Eclipse ALO Valves are recommended for installation in gas lines feeding nozzle mix burners as a means of gas flow adjustment for the desired air/gas ratio.

Links:

Industrial Furnace Gas Burners

Locktite Valves
Eclipse Locktite Valves
 

The Eclipse Inc. 200 LockTite valves are manually opening valves that automatically shut off the gas supply to a combustion system when any interlocking limit switch opens. The valve handle cannot be reset until the condition causing the open switch is corrected and all limit switches are closed. Typical limit switches include air pressure, gas pressure, temperature limit, and flame monitoring contacts.

In the event of a power failure, the valve immediately closes. Series 200 LT valves include two visual indicators of "open" or "closed" position: a red "flag" visible in the plastic dome on top of the valve; and the reset handle position as indicated by cast markings on the operator case. These valves also include two SPDT micro-switches that can be used for auxiliary circuits. Two contacts are made when the valve opens, and two are made when the valve is closed.

Links:

Industrial Furnace Gas Burners

Autotite Valves
Eclipse Autotite Valves
 

AutoTite shut-off valves set the industry standard with broad NEMA approval.

Engineered and built with the precision you've come to expect from Eclipse, each AutoTite 2000AT valve is Performance Certified - 100% factory tested before shipment.

For medium pressure range applications, you can't find automatic gas shut-off valves with more installation flexibility, operational conveniences, and peace-of-mind safety features.

Links:

Industrial Furnace Gas Burners

Blast Gate Valve
Eclipse Blast Gate Valve
 

Eclipse Blast Gates are sturdy, inexpensive manual control valves for use with low pressure air up to 5 psig.

Links:

Industrial Furnace Gas Burners

Manual Shutoff Valves
Eclipse Manual Shutoff Valves
 

Eclipse Manual Shut Off Gas Valves.

Various Types: Lever Handle Valves, Brass Ball Valves, Brass Ball Valve with Side Tap and more.

Links:

Industrial Furnace Gas Burners

BV-Pak Packaged Butterfly Valves
Eclipse BV-Pak Packaged Butterfly Valves
 

The Eclipse Packaged Butterfly Valve incorporates an Eclipse Trilogy Series Actuator mounted to a standard Eclipse butterfly valve. The new innovative support provides a robust universal solution with an "easy to see" position indicator. This package is the perfect solution for industrial burner control. Eclipse simplifies selection and ordering in this single source component purchase. Equipment sizing, mounting, and setup are all made easier.

Links:

Industrial Furnace Gas Burners

Disk Type Check Valves
Eclipse Disk Type Check Valves
 

Eclipse Series 1000 Disc Type Check Valves are designed to prevent reverse flow of gas or air, however, they are not designed for tight shut-off. They are especially suited for use in distribution systems and industrial plants.

Links:

Industrial Furnace Gas Burners

Configured Packaged Valve Trains
Eclipse Configured Packaged Valve Trains
 

Eclipse valve trains are rated for 110-120V / 50-60 Hz operation and are designed to meet the requirements of NFPA 86 - 2003 or Industrial Risk Insurers (IRI) IM.4.2.0. The IRI version includes either a vent valve or a valve proving system.

Standard components of all valve train sizes include safety shut-off valves, manual shut-off valves, high & low pressure switches, visual position indicators and pressure taps for valve seat leak testing and in-line strainers. Optional components consist of regulators, valve leak test systems, upstream and downstream gauges (2 - 1/2" face diameter) and pilot gas trains (1/2" or 3/8").

Links:

Industrial Furnace Gas Burners

Standard Valve Train Segments
Eclipse Standard Valve Train
 

The Eclipse Standard Valve Train Segments are designed to install faster, operate safer and deliver proven reliability for global applications. Eclipse Standard Valve Train Segments are offered in the NFPA series with UL, CSA and FM approved components or in the EN 746-2 series utilizing CE marked components.

All Standard Valve Train Segments are available in nominal pipe sizes from 1/2” (25 mm) through 8” (200 mm). Threaded and flanged models are available depending on the pipe size specified.

Links:

Industrial Furnace Gas Burners